Amc72L-E4/Kc AC Three Phase 3p4w Digital Multifunction Programmable Smart Intelligent Electric RS485 Modbus RTU Energy Power Meter Kwh Meter for Switch Cabinet
Package size per unit product 17.00cm * 15.00cm * 13.00cm Gross weight per unit product 0.580kg Product DescriptionAMC72;
Basic Info
Model NO. | AMC72L-E4/KC |
Electric Equipment | Three-phase Four-wire |
Theory | Electronic Meter |
Power Meter Connection | Terminal |
Measured Signal | Pulse Peak |
Type | Energy Meter |
Certification | RoHS, ISO, CE |
Customized | Customized |
Product Name | 3 Phase Multifunction Harmonic Energy Power Monito |
Brand | OEM ODM |
Auxiliary Power Supply | AC 220V |
Reference Frequency | 45~65Hz |
Input Voltage | 230/400V |
Accuracy | Class 1 |
Certificate | Ce |
Transport Package | Fob Shanghai |
Specification | 96*96mm |
Trademark | ACREL |
Origin | China |
HS Code | 9028301400 |
Production Capacity | 10000PCS/Per Month |
Packaging & Delivery
Package size per unit product 17.00cm * 15.00cm * 13.00cm Gross weight per unit product 0.580kgProduct Description
AMC72L-E4/KC lcd intelligent power collection and monitoring energy meterGeneralDimensionTechnical Parameters1. Function Overview
Function | Description&Value |
Measurement | Three-phase AC kWh, kVarh, Active Power, Reactive Power, Forward&Reverse Power, Current, Voltage, Zero Sequence Voltage, Zero sequence Current, Voltage-phase Angle, Voltage&Current Unbalance, Power Factor,Harmonic, Frequency |
Display | LCD display |
Communication (Optional) | RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity) Baud Rate 1200~38400 bps etc. |
Alarm Output (Optional) | 1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc. |
Analog Output (Optional) | 1~5V DC or 4~20mA DC |
DI/DO Switching (Optional) | DI (Digital input): 2-channel or 4-channel dry contact digital input with built in power supply DO (Digital output): 2-channel digital output with NO relay contact. Capacity: 3A/30V DC,3A/250V AC |
2. Main Parameters
Parameter | Description&Value | |
Input | Rated Voltage | AC Voltage Input: 400V AC L-L (via direct connetion); 100V AC L-L (via -/100V AC PTs) |
Rated Current | AC Current Input: 5A AC or 1A AC (via -/5A AC or -/1A AC CTs) | |
Overload | Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second | |
Frequency | 45~65Hz | |
Power Consumption | Power consumption of each current&voltage input circuit is less than 0.5VA | |
Measuring Accuracy | Voltage | 0.2% |
Current | 0.2% | |
Active Power | 0.5% | |
Reactive Power | 1.0% | |
kWh | 0.5% | |
kVarh | 1.0% | |
Frequency | ±0.05Hz | |
Harmonic | ±1% | |
Power Supply | Voltage Range | 85-265V AC/DC; 24V or 48V DC (±20%) |
Power Consumption | ≤10VA | |
Insulation resistance | ≥ 100MΩ | |
Power frequency withstand voltage | Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min; Between Power supply,switching output,Current Input,voltage Input AC 2 kV 1min; Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min; |
3. Environment
Condition | Description&Value |
Temperature | Operation: -25ºC~+65ºC; Storage: -40°C ~+80°C |
Humidity | ≤95%RH,no condensation,without corrosive gas |
Altitude | ≤ 2500m |
Wiring
Wiring method of 3 phase 3 wire | Wiring method of 3 phase 4 wire |