62A DIN Rail 230V Adjustable Over Voltage and Under Voltage Protective Device Protector Relay Zoii Electric
Overview Product Parameters1.General IntroductionThe multifunctional self-resetting dual display protector integrates ov;
Basic Info
Poles Number | 2 |
Type | Circuit Breaker |
Function | Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Under and Over Voltage Protection |
Certification | ISO9001-2000, CE |
Rated Operating Current | 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A |
Rated Operating Voltage | AC230V |
Electrical Life | > 100,000 Times |
Frequency | 50Hz |
Display | Digital |
Transport Package | Standard Export Packing |
Specification | 51*35*60mm |
Trademark | ZOLL |
Origin | China |
HS Code | 8536500000 |
Production Capacity | 10000PCS/Month |
Product Description
Rated voltage | 220VAC 50Hz |
Rated current | 1A-63A adjustable (default 40A) |
Overvoltage action cut-off value | 240V-300VAC can be set (default 270VAC) |
Overvoltage action cut-off value | 140V-200VAC can be set (default 1 70VAC) |
Overcurrent action cut-off value | 63A: 1A-63A can be set (default 40A) / 40A: 1 A-40A can be set (default 40A) |
Transmission delay time after power-on and power-off | 5-300S adjustable (default 5S) |
Boot delay time | 1-300S adjustable (default 5S) |
Reset delay time after overcurrent protection | 30-300s adjustable (default 30s) |
Product overcurrent delay time | 6s (overcurrent time greater than this time will be confirmed as overcurrent and provide protection) |
Own power consumption | less than or equal to 2W |
Electrical machinery life | greater than or equal to 100,000 times |
6. Product settingsNote: If the keyboard is longer than 60 seconds at any position before saving, the operating system will abandon all settingsand restart.
7. UseAfter the protector is installed, the user can wire it, and select the wire section that meets the standardaccording to the setting current of the protector. Note that the input and output wires of the protectorcannot be connected incorrectly to avoid damage to the product or power failure.8. Precautions8. 1 When performing various current operation or tests, users should follow the relevant regulations andpay attention to the following matters to ensure the correct and safe use of this product.
8.2 According to the product standard, the input and output terminals are connected correctly (the loadcurrent should be less than the protection current value of the product)8.3 The neutral wire N cannot be connected wrongly and must be connected reliably, otherwise theprotector cannot work normally.8. 4 Before turning on the power, carefully check whether the wiring is correct, whether the load sizematches the current protection value of the product, and whether the wiring screws are tightened,otherwise the product will be damaged.8.5 After the product is connected to the power supply, please do not touch the live parts to avoid electricshock.8.6 This product needs to cooperate with micro-break to play a short-circuit protection function, otherwisethe product will not be able to provide protection when a short-circuit occurs in the load of the product.8.7 Since the product has an automatic reset function, after the product is protected and activated, theload (electrical appliances) should be removed immediately, and the circuit should be checked, otherwisethe product will frequently switch on the load and disconnect the load, which will eventually damage theproduct or electrical appliances due to frequent overloads for a long time.8.8 The product should be protected from moisture and dust when it is not used for a long time. Theproduct should be tested as described above before using, and it can be used while it is normal.8.9 This product has no isolation function. Please disconnect the front-level circuit breaker switch whenrepairing the circuit.8. 10 The zero line (N line) of this product is directly connected and has no disconnection function.8. 11 This product has no over-current short-circuit breaking capacity. Please install a small circuitbreaker such as DZ-47 or C65 at the front of the line as over-current protection.8.12 If the actual setting is different from this manual due to product upgrade, please contact ourcompany. Product upgrade will not be notified separately.Application
9. Product wiring diagramCertificates
FAQQ1: Are you a factory or trading company
A1: We are a factory, we can guarantee our price is first-hand, very cheap and competitive.
Q5: What is your main products?
A5: Solar Power system accessories ,The wide range products under manufacturing covers such as AC&DC Surge Protective Device(SPD),AC&DC Miniature Circuit Breaker(MCB),AC&DC Moulded Case Circuit Breaker(MCCB),Voltage & Current Protector,DC FUSE,Solar connector ,Solar cable,combiner box etc.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge.
Q2: How does your factory do regarding quality control?
A2: All the products will be 100% checked before the shipment.
Q:How's the delivery?Because I really need them is urgently?
A: Samples cost 1-2 days. Bulk order cost 12-15 days.
You may also like
Send inquiry
Send now